CO2 Sensor CM1106-C | |
---|---|
Operating Principle | TC (Thermal Conductivity) |
Detection Category | H2 |
Measurement Range | 0~10%vol( 0~4%vol accuracy guaranteed) |
Accuracy | H2 vol.% in air ≤4%: ±0.4vol.% H2 vol.% in air>4%: ±10% @-40℃-85℃, 0%-95%RH |
Power Supply | 9V~16V |
Average Working Current | ≤30mA @12V |
Working Pressure | 80~120kPa |
Resolution | 1ppm |
Response Time | <1s |
Start Up Time | <200ms |
Digital Output | CAN/PWM |
Working Condition | -40~85°C, 0%~99%RH (non-condensing) |
Storage Condition | -40~95°C, 0%~99%RH (non-condensing) |
Design Lifetime | >10 years (continually working) |
You can contact Cubic by telephone or email, or you can submit an online Request for Quotation Form.
For Sales: sales@gassensor.com.cn
For Administration: info@gassensor.com.cn