Contact
fix6.png
Home > Product > IAQ Controller & Monitor

IAQ Controller & Monitor

Product0
Wall Mount2
Desktop1
Duct1
USB1
Get the Products

Table Overview for Cubic IAQ Monitor and Controller

Model Working principal Output Parameter Measurement Range Accuracy Communication Protocol Recommendations
AM7000.png AM7000.png
Air Quality Monitor
AM7000

AM7000

NDIR
Light scattering
Electrochemical
PM
CO2
Temperature
Humidity
HCHO(optional)
VOC(optional)
CO2: 0~5000ppm
PM2.5: 0~999μg/m³
HCHO:0~1PPM
VOC:0~3level
PM:
≤100μg/m³: ±10μg/m³ ; >100μg/m³: ±10% of reading
CO2:
±(50ppm+5% of reading)

WIFI & Bluetooth

Smart Wifi Device with APP & Cloud support
Accurate and reliable measurement
Convenient calibration
Real-time output PM,CO2,RH&T (VOC,HCHO optional)
Desktop monitor, USB power supply
OEM/ODM is available

more.png
Specifications Features
Output Parameter
PM
CO2
Temperature
Humidity
HCHO(optional)
VOC(optional)
Measurement Range
CO2: 0~5000ppm
PM2.5: 0~999μg/m³
HCHO:0~1PPM
VOC:0~3level
Accuracy
PM:
≤100μg/m³: ±10μg/m³ ; >100μg/m³: ±10% of reading
CO2:
±(50ppm+5% of reading)
Communication Protocol

WIFI & Bluetooth

AM6108B.png AM6108B.png
Wall mount HVAC Transmitter with Display
AM6108B

AM6108B

NDIR
Light scattering
MOX
PM
CO2
VOC
Temperature
Humidity
CO2: 0~5000ppm;
PM2.5/PM10: 0~999μg/m³;
VOC:0~3level
PM:
PM2.5: ≤100μg/m³; ±10μg/m³, >100μg/m³: ±10% of reading
CO2:
±(50ppm+5% of reading) /±(30ppm+3% of reading) is optional
RS485 Modbus-RTU, BACnet-MSTP, Wi-Fi

Real-time output PM, CO2, RH&T, VOC
RS485 with control function
Data transfer via Wi-Fi available
OEM available

more.png
Specifications Features
Output Parameter
PM
CO2
VOC
Temperature
Humidity
Measurement Range
CO2: 0~5000ppm;
PM2.5/PM10: 0~999μg/m³;
VOC:0~3level
Accuracy
PM:
PM2.5: ≤100μg/m³; ±10μg/m³, >100μg/m³: ±10% of reading
CO2:
±(50ppm+5% of reading) /±(30ppm+3% of reading) is optional
Communication Protocol
RS485 Modbus-RTU, BACnet-MSTP, Wi-Fi
Wall-Mount CO2 Transmitter Wall-Mount CO2 Transmitter
Wall-Mount CO2 Transmitter
AM6208W

AM6208W

NDIR CO2 0~5000ppm ±(30ppm+3% of reading)
@0~50℃,0~2000ppm
Analog output:
0-10 VDC, 4-20mA

High accuracy,  in conformity with RESET Standard Grade A & California Title 24
Analog output: 0-10 VDC, 4-20mA
PM,VOC,RH&T optional OEM/ODM available

more.png
Specifications Features
Output Parameter
CO2
Measurement Range
0~5000ppm
Accuracy
±(30ppm+3% of reading)
@0~50℃,0~2000ppm
Communication Protocol
Analog output:
0-10 VDC, 4-20mA
Duct CO2 Transmitter Duct CO2 Transmitter
Duct CO2 Transmitter
AM6208D

AM6208D

NDIR CO2 0~5000ppm ±(30ppm+3% of reading)
@0~50℃,0~2000ppm
Analog output:
0-10 VDC, 4-20mA

High accuracy, in conformity with RESET Standard Grade A & California Title 24
Analog output: 0-10 VDC, 4-20mA
PM,VOC,RH&T optional
OEM/ODM available

more.png
Specifications Features
Output Parameter
CO2
Measurement Range
0~5000ppm
Accuracy
±(30ppm+3% of reading)
@0~50℃,0~2000ppm
Communication Protocol
Analog output:
0-10 VDC, 4-20mA
CM01.png CM01.png
Mini USB CO2 Detector
CM01

CM01

NDIR CO2 400~5000ppm ±(50ppm+5% of reading)
USB

Standard USB plug-in interface, convenient to use
4-Digit screen display for real-time concentration
Alarm when CO2 concentration exceeds the set value

more.png
Specifications Features
Output Parameter
CO2
Measurement Range
400~5000ppm
Accuracy
±(50ppm+5% of reading)
Communication Protocol
USB
Load More

IAQ Controller & Monitor

Load More
This website uses cookies to improve your user experience. By using this site, you consent to the use of cookies. You can find more information in our Privacy Policy.