Model |
Light Source |
Measurement Range |
Accuracy |
Communication |
Dimensions |
Recommendations |
Small Size Laser Particle Sensor PM2012SE-A/PM2012SE-B
PM2012SE-A/B
|
Laser |
0~5000μg/m³
|
PM1.0/PM2.5:0~100μg/m³, ±10μg/m³
101~500μg/m³, ±10% reading
PM10:0~100μg/m³, ±25μg/m³
101~500μg/m³, ±25% reading
|
UART, I²C |
W38*H35*D12
(mm)
|
Small size
Inlet and outlet in same or opposite side
|
|
Specifications
Features
- Measurement Range
- 0~5000μg/m³
- Accuracy
PM1.0/PM2.5:0~100μg/m³, ±10μg/m³
101~500μg/m³, ±10% reading
PM10:0~100μg/m³, ±25μg/m³
101~500μg/m³, ±25% reading
- Communication
- UART, I²C
- Dimensions
- W38*H35*D12
(mm)
|
Anti-dust Laser Particle Sensor PM2016
PM2016
|
Laser |
0~1000μg/m³
|
PM1.0/PM2.5: 0~100μg/m³, ±10μg/m³
101~500μg/m³, ±10% reading
PM10: 0~100μg/m³, ±25μg/m³
101~500μg/m³, ±25% reading
|
UART, I²C |
W40.7*H40.7*D12.2
(mm)
|
Better identification of PM1.0, PM2.5, PM10 based on the API (Auto particle identification) innovation technology
High performance automotive standard laser diode, better accuracy for PM10 with real measurement
High accuracy at the low concentration.
|
|
Specifications
Features
- Measurement Range
- 0~1000μg/m³
- Accuracy
PM1.0/PM2.5: 0~100μg/m³, ±10μg/m³
101~500μg/m³, ±10% reading
PM10: 0~100μg/m³, ±25μg/m³
101~500μg/m³, ±25% reading
- Communication
- UART, I²C
- Dimensions
W40.7*H40.7*D12.2
(mm)
|
Low Power Particle Sensor PM2105L
PM2105L
|
Laser |
0~1000μg/m³
|
PM1.0/PM2.5: 0~100μg/m³, ±10μg/m³
>100μg/m³, ±10% reading
PM10: 0~100μg/m³, ±30μg/m³
101~1000μg/m³, ±30% reading
|
UART, I²C |
W42*H35*D23.7
(mm)
|
Lower power consumption, less than 0.9mA available. Suitable for battery-powered devices
The high performance fan: 3S fan speed stable, 4S stable reliable reading output
Real measurement for PM10
|
|
Specifications
Features
- Measurement Range
- 0~1000μg/m³
- Accuracy
PM1.0/PM2.5: 0~100μg/m³, ±10μg/m³
>100μg/m³, ±10% reading
PM10: 0~100μg/m³, ±30μg/m³
101~1000μg/m³, ±30% reading
- Communication
- UART, I²C
- Dimensions
W42*H35*D23.7
(mm)
|
Laser Particle Sensor PM2008-API
PM2008-API
|
Laser |
0~5000μg/m³
|
PM1.0&PM2.5: 0 ~35μg/m³, ±5μg/m³
35μg/m³~500μg/m³, ±15% of reading
PM10: 0 ~100μg/m³, ±30μg/m³
101 ~500μg/m³, ±30% of reading
|
UART, I²C |
W47.8*H36.8*D12
(mm)
|
High accuracy @ <35ug/m³: ±5ug/m³
API (Auto particle identification) innovation technology
Air inlet and outlet on the same side
|
|
Specifications
Features
- Measurement Range
- 0~5000μg/m³
- Accuracy
PM1.0&PM2.5: 0 ~35μg/m³, ±5μg/m³
35μg/m³~500μg/m³, ±15% of reading
PM10: 0 ~100μg/m³, ±30μg/m³
101 ~500μg/m³, ±30% of reading
- Communication
- UART, I²C
- Dimensions
W47.8*H36.8*D12
(mm)
|
Laser Particle Sensor with Screw Hole PM2008M-M
PM2008M-M
|
Laser |
0~5000μg/m³
|
PM1.0&PM2.5: 0 ~35μg/m³, ±5μg/m³
35μg/m³~500μg/m³, ±15% of reading
PM10: 0 ~100μg/m³, ±30μg/m³
101 ~500μg/m³, ±30% of reading
|
UART, I²C |
W48*H40*D12
(mm)
|
High accuracy @ <35ug/m³: ±5ug/m³
Mounting ears for easy installation with screw
|
|
Specifications
Features
- Measurement Range
- 0~5000μg/m³
- Accuracy
PM1.0&PM2.5: 0 ~35μg/m³, ±5μg/m³
35μg/m³~500μg/m³, ±15% of reading
PM10: 0 ~100μg/m³, ±30μg/m³
101 ~500μg/m³, ±30% of reading
- Communication
- UART, I²C
- Dimensions
W48*H40*D12
(mm)
|
LED Particle Sensor PM1003
PM1003
|
LED infrared |
0~500μg/m³
|
PM2.5: 0~100 μg/m³:±30μg/m³;
100~500 μg/m³: ±30% of reading
|
PWM, UART |
W59*H45*D20
(mm)
|
Temperature compensation within whole measurement range
|
|
Specifications
Features
- Measurement Range
- 0~500μg/m³
- Accuracy
PM2.5: 0~100 μg/m³:±30μg/m³;
100~500 μg/m³: ±30% of reading
- Communication
- PWM, UART
- Dimensions
W59*H45*D20
(mm)
|
LED Particle Sensor with Dust Correction PM1006K
PM1006K
|
LED infrared |
0~1000μg/m³
|
PM2.5: 0~ 100μg/m³, ±20μg/m³
100~1000μg/m³, ±20% of reading
PM1.0/PM10: No accuracy definition
|
UART,PWM |
W46.2*H34.1*D18
(mm)
|
Built-in MCU, real-time output PM1.0, PM2.5, PM10 in μg/m3
Auto lens dust deposition correction
|
|
Specifications
Features
- Measurement Range
- 0~1000μg/m³
- Accuracy
PM2.5: 0~ 100μg/m³, ±20μg/m³
100~1000μg/m³, ±20% of reading
PM1.0/PM10: No accuracy definition
- Communication
- UART,PWM
- Dimensions
W46.2*H34.1*D18
(mm)
|
LED Dust Sensor for Vacuum Cleaner PM1009
PM1009
|
LED infrared |
0-10000pcs
|
No accuracy definition |
UART |
Main control PCBA
( L26.5*W16.0*H1.0 mm)
|
4-channel particle count output: 10μm-60μm, 60μm-180μm, 180μm-500μm and 500μm;
Suitable for vacuum cleaner, sweeper robot
|
|
Specifications
Features
- Measurement Range
- 0-10000pcs
- Accuracy
- No accuracy definition
- Communication
- UART
- Dimensions
Main control PCBA
( L26.5*W16.0*H1.0 mm)
|
LED Dust Sensor for Floor Scrubber PM1010
PM1010
|
LED infrared |
0-100 levels
|
No accuracy definition |
UART |
Main control PCBA
( L26.5*W16.0*H1.0 mm)
|
Sewage pollution level output through UART protocal
Suitable for floor scrubber, floor washing machine
|
|
Specifications
Features
- Measurement Range
- 0-100 levels
- Accuracy
- No accuracy definition
- Communication
- UART
- Dimensions
- Main control PCBA