Model |
Light Source |
Measurement Range |
Accuracy |
Communication |
Dimensions |
Recommendations |
PM2012SE-A/B
|
Laser |
0~5000μg/m³
|
PM1.0/PM2.5:0~100μg/m³, ±10μg/m³
101~500μg/m³, ±10% reading
PM10:0~100μg/m³, ±25μg/m³
101~500μg/m³, ±25% reading
|
UART, I²C |
W38*H35*D12
(mm)
|
Small size
Inlet and outlet in same or opposite side
|
|
PM2016
|
Laser |
0~1000μg/m³
|
PM1.0/PM2.5: 0~100μg/m³, ±10μg/m³
101~500μg/m³, ±10% reading
PM10: 0~100μg/m³, ±25μg/m³
101~500μg/m³, ±25% reading
|
UART, I²C |
W40.7*H40.7*D12.2
(mm)
|
Better identification of PM1.0, PM2.5, PM10 based on the API (Auto particle identification) innovation technology
High performance automotive standard laser diode, better accuracy for PM10 with real measurement
High accuracy at the low concentration.
|
|
PM2105L
|
Laser |
0~1000μg/m³
|
PM1.0/PM2.5: 0~100μg/m³, ±10μg/m³
>100μg/m³, ±10% reading
PM10: 0~100μg/m³, ±30μg/m³
101~1000μg/m³, ±30% reading
|
UART, I²C |
W42*H35*D23.7
(mm)
|
Lower power consumption, less than 0.9mA available. Suitable for battery-powered devices
The high performance fan: 3S fan speed stable, 4S stable reliable reading output
Real measurement for PM10
|
|
PM2008-API
|
Laser |
0~5000μg/m³
|
PM1.0&PM2.5: 0 ~35μg/m³, ±5μg/m³
35μg/m³~500μg/m³, ±15% of reading
PM10: 0 ~100μg/m³, ±30μg/m³
101 ~500μg/m³, ±30% of reading
|
UART, I²C |
W47.8*H36.8*D12
(mm)
|
High accuracy @ <35ug/m³: ±5ug/m³
API (Auto particle identification) innovation technology
Air inlet and outlet on the same side
|
|
PM2008M-M
|
Laser |
0~5000μg/m³
|
PM1.0&PM2.5: 0 ~35μg/m³, ±5μg/m³
35μg/m³~500μg/m³, ±15% of reading
PM10: 0 ~100μg/m³, ±30μg/m³
101 ~500μg/m³, ±30% of reading
|
UART, I²C |
W48*H40*D12 (mm)
|
High accuracy @ <35ug/m³: ±5ug/m³
Mounting ears for easy installation with screw
|
|
PM1003
|
LED infrared |
0~500μg/m³
|
PM2.5: 0~100 μg/m³:±30μg/m³;
100~500 μg/m³: ±30% of reading
|
PWM, UART |
W59*H45*D20 (mm)
|
Temperature compensation within whole measurement range
|
|
PM1006K
|
LED infrared |
0~1000μg/m³
|
PM2.5: 0~ 100μg/m³, ±20μg/m³
100~1000μg/m³, ±20% of reading
PM1.0/PM10: No accuracy definition
|
UART,PWM |
W46.2*H34.1*D18 (mm)
|
Built-in MCU, real-time output PM1.0, PM2.5, PM10 in μg/m3
Auto lens dust deposition correction
|
|
PM1009
|
LED infrared |
0-10000pcs
|
No accuracy definition |
UART |
Main control PCBA
( L26.5*W16.0*H1.0 mm)
|
4-channel particle count output: 10μm-60μm, 60μm-180μm, 180μm-500μm and 500μm;
Suitable for vacuum cleaner, sweeper robot
|
|
PM1010
|
LED infrared |
0-100 levels
|
No accuracy definition |
UART |
Main control PCBA
( L26.5*W16.0*H1.0 mm)
|
Sewage pollution level output through UART protocal
Suitable for floor scrubber, floor washing machine
|
|