CO2 Sensor CM1106-C | |
---|---|
Detecting Principle | CO2: Non-dispersive infrared spectroscopy technology (Dual Beam NDIR) CO: Metal oxide semiconductor technology(MOX) Pressure: MEMS Temperature: NTC |
Measurement Gas | CO2, CO |
Measurement Range | CO2: 0ppm-5000ppm CO: 1-1000ppm Pressure: 40kPa~180kPa Temperature: -20 ~ 120℃ |
Resolution | 1ppm |
Accuracy | CO2: ±(50ppm+3% reading) CO: ±40ppm or ±30%reading, larger value as criteria Pressure: ±1kPa Temperature: ±2℃ |
Date Refresh | ≤1s |
Response Time | T90≤25s |
Communication Port | CAN (LIN/UART/Analog Voltage optional) |
Working Condition | -40℃~+85℃, 0~99%RH(Non-condensing) |
Storage Condition | -40℃~+110℃, 0~99%RH(Non-condensing) |
Working Pressure | 40kPa~180kPa |
Power Supply | 9~16VDC, Standard Voltage +12VDC |
Average Working Current | ≤100mA, @+12VDC |
Quiescent Current | <100uA, Sleep Mode |