CO2 Sensor CM1106-C | |
---|---|
Operating principle | NDIR(dual channel non-dispersive Infrared) technology MEMS (Microelectronic Mechanical Systems) LSD(Laser scattering) |
Measurement target | CO2,CO/HC/H2,PM2.5,Temperature |
Measurement range | CO:0ppm~1000ppm(Display up to 3Kppm) CO2:0ppm~10000ppm(Display up to 60Kppm) PM2.5:0~5000ug/m³ Temperature: -40℃~120℃ |
Resolution | CO2/CO/HC/H2:1ppm PM2.5:1ug/m³ Temperature:0.1℃ |
Accuracy | CO2: ±(50ppm+5%reading) CO:±40ppm or ±30% max reading PM2.5:≤100μg/m³: ±15μg/m³;>100μg/m³: ±15% reading Temperature:±2℃ |
Response time | T90≤15s |
Working temperature | -40~+85℃,0-95%RH (non-condensing) |
Storage temperature | -40~+95℃,0-95%RH (non-condensing) |
Working pressure | 80kPa~120kPa |
Power supply | 9~16 VDC, standard voltage 12 VDC |
Working current | ≤100mA @12VDC |
Low powe consumption mode | ≤50mA @12VDC |
Standby current | ≤100μA |
Communication | CAN |
IP rating | IP54 |
Dimension | 91*84*34 (mm) |
You can contact Cubic by telephone or email, or you can submit an online Request for Quotation Form.
For Sales: sales@gassensor.com.cn