ODM  Metabolism Analyzer Solution(1).png

ODM Metabolism Analyzer Solution

Cubic is offering ODM service for customers who is seeking for metabolism analyzer solutions. By combining Cubic precision sensor system with Cubic team developed operation software, this ODM metabolism analyzer solution could integrate TDLAS O2 concentration measurement technology, NDIR CO2 concentration measurement technology and ultrasonic flow rate measurement technology to ensure precision O2 and CO2 concentration measurement, as well as flow rate measurement. The intelligent algorithms could achieve real-time sampling and calculation of human exhaled carbon dioxide (VCO2) and inhaled oxygen volume (VO2), also support the accurate calculation of respiratory quotient and basal metabolic rate, and help to evaluate metabolic balance of the human body at the same time.


In clinical application, metabolic testing could provide accurate data support on nutritional plans, and offer scientifically effective data support for specific patient's treatment and rehabilitation.


In public healthcare applications, nutrient metabolism testing determines the degree of deficiency or excess of major nutrients in the body, which could guide people to create a more healthy lifestyle.


So this set of ODM metabolism analyzer solution is very suitable for customers who is related with cardiopulmonary function and public healthcare.


Show More

Features

  • Based on Indirect Calorimetry Principle for precise measurement.
  • Combination of Cubic self-developed sensing technology and diagnostic software.
  • Automatic calibration for the whole testing system.
  • With automatic correction of temperature, humidity, and pressure during metabolism testing.
  • Long lifespan up to 10 years.
  • OEM and ODM service are available.

Specifications

CO2 Sensor CM1106-C
Sampling Rate 300ml/min
Minute Oxygen Uptake Measurement Range 10-1000ml/min
Minute Carbon Dioxide Measurement Range 10-1000ml/min
Respiratory Quotient (RQ) Range 0-2.0
Resting Energy Expenditure (REE) Range 0-7200kcal/24 hr
Minute Oxygen Uptake Measurement Accuracy ±3%
Minute Carbon Dioxide Measurement Accuracy ±3%
Respiratory Quotient (RQ) Accuracy ±5%
Resting Energy Expenditure (REE) Accuracy ±3%