CO2 Sensor CM1106-C | |
---|---|
Operating principle | Laser scattering |
Measured particle size | 0.3μm~10μm |
Measurement range | 0~1000μg/m³ |
Resolution | 1μg/m³ |
Working condition | -10°C ~ 60°C, 0-95%RH (non-condensing) |
Storage condition | -40°C ~ 80°C, 0-95%RH (non-condensing) |
Measurement accuracy for PM1.0&PM2.5 | 0 ~100μg/m³, ±10μg/m³ >100μg/m³, ±10% of reading Condition: 25±2℃, 50±10%RH, Reference instrument: GRIMM, Dust source: Cigarette |
Measurement accuracy for PM10 | 0 ~100μg/m³, ±30μg/m³ 101 ~1000μg/m³, ±30% of reading Condition: 25±2℃, 50±10%RH, Reference instrument: GRIMM Dust source: Cigarette |
Response time | 1 sec |
First time to reliable reading | 4 sec |
Power supply | DC 5V±0.1V Ripple wave<50 mV |
Working current | <53 mA |
Standby current | <5 mA |
Dimensions | 42×35×23.7 mm |
Digital output 1 (default) | UART_TTL_3.3V(default) I²C_3.3V/5V(default) |
Digital output 2 | PWM (customized) |
Output method | Default by active output after powering on, sampling time interval should be over 1,000 ms |
MTTF | 37,297 hrs (continuous turn on) |
You can contact Cubic by telephone or email, or you can submit an online Request for Quotation Form.
For Sales: sales@gassensor.com.cn
For Administration: info@gassensor.com.cn