EMAIL

| CO2 Sensor CM1106-C | |
|---|---|
| Operating Principle | PM (Particulate Matter): Infrared Scattering |
| Detection Category | PM (Particulate Matter) |
| Measurement Range | PM:0-10000ug/m³ |
| Resolution | PM:1ug/m³ |
| Accuracy | PM:±15% of reading @5000ug/m3 (room temperature) |
| Data Refresh Time | ≤1s |
| Digital Output | CAN2.0 |
| Design Lifetime | 10 Years |
| Working Condition | -40℃~+85℃;0~99%RH (non-condensing) |
| Storage Condition | -40℃~+95℃;0~99%RH (non-condensing) |
| Working Pressure | 60kPa~120kPa |
| Power Supply | 6~16VDC (standard voltage 12V DC) |
| Average Working Current | Normal Mode:≤30mA,@+12VDC(sensor continuous working) Low Power Mode:≤500uA,@+12VDC(sensor works intermittently, and the interval is 12.2 seconds) |
You can contact Cubic by telephone or email, or you can submit an online Request for Quotation Form.